LAPP GROUP NORTH AMERICA

CSS Accordian Menu Css3Menu.com

NAVIGATE THE CATALOG BY SECTIONS
Oil Resistant Cables Flexible Tray Cable Continuous Flex Control Cable Continuous Flex Data Cable Torsional Robotic Cable High Temperature Cable Flexible Cables for Drives, Motors, & Assemblies Flexible Signal & Control Cable Ethernet Cable ../Cables & Cordage Pendant & Reel Cable UL Single Core & Hook-up Wire UL Single Core & Hook-up Wire EPIC Circular Connectors EPIC® Pin & Sleeve Connectors SKINTOP® Strain Relief Tubing & Sleeving Conduit & Accessories Cable Marking Systems Cable Track Lapp Systems Technical Data

Strain Relief Cord Connectors

 

SKINTOP®
Liquid Tight, Non-Metallic Strain Relief Cable Glands
Secured by a Single Turn of the Hand

 

SKINTOP Strain Relief

Cap nut with ergonomically designed gripping grooves. The gripping surfaces are generously dimensioned for spanners. Integral locking feature for vibration-resistant assembly.

Neoprene sealing
for a hermetic seal (IP68)*. Every SKINTOP® version is available with reducing seal insert for smaller cable diameters.


Lamellar design
for optimum strain relief and protection of the cable. Widely variable clamping range, therefore only a few gland sizes are necessary.


Multiple trapezoidal thread
for secure and instant assembly.


Integral sealing lips
for a water tight junction with the housing.

Shown here are the carefully matched components of the SKINTOP® screw-type cable glands. It is precisely these parts which guarantee optimum reliability.

 

Even more:
With SKINTOP® you can install the cable in an instant. Just feed it in, turn nut until tight - ready. So your cable is centered, hermetically sealed and completely strain relieved with a turn of the hand. If you do not wish to use your hands, you can of course work with a spanner wrench or SKINTAMTIC® RZ tool. Either way, with SKINTOP® you can achieve maximum reliability. To ensure that this remains so, SKINTOP® quality is continuously monitored. A quality which has brought us many international approvals.

 

Resistance Properties:

Rated Temperature:

SKINTOP® NPT & PG -20ºC to +80ºC
  SKINTOP® Metric  
 
static:
-40ºC to 100ºC
 
dynamic:
-20ºC to 100ºC

Chemical:

+Alcohols
+Keytones

 

+Aromatic Hydrocarbons
+Motor Fuels

+ = resistant

+Ethers
+Weak Alkali Solutions

o = with limited resistance

+Benzene
-Strong Alkali Solutions

 - = non-resistant

oChlorinated hydrocarbons
+Petroleum Oils

 

+Esters
+Weak Acids

 

+Grease, animal-vegetable
-Strong Acids

 

+Flourinated hydrocarbons
+Trichlorethylene

Testing:

SKINTOP®
 

 

Incandescent wire test to IEC 695, Part 2-1

 

Test Temperature 750°C
 

 

Strain relief to DIN VDE 0619
 

 

Protection Class IP 68,
 

 

Test to DIN 40050 and 40052
 

International Approvals:

UL #E146370
CSA #LR50370-10
VDE #57986
SEV #100989
     

 * All IP Ratings are dependent on proper installation by the user